OLT1000-04V-302

+ Free Shipping
OLT1000-04V-302 is an open-loop current transducer for DC, AC, and pulsed currents up to ±3000 A, with +/-4 V analog output at 1000 A nominal current, 50 kHz bandwidth and >3 kVAC galvanic isolation.

Datasheet PDF : OLT1000-04V-302.pdf

Categories: ,
OLT1000-04V-302 is designed for accurate measurement of DC, AC, and pulsed currents up to ±3000 A. It provides galvanic isolation between the primary and measurement circuits greater than 3 kVAC.The sensor delivers a proportional analog voltage output, with +/-4 V corresponding to 1000 A nominal primary current. Its 50 kHz bandwidth, fast response time and low offset make it suitable for industrial power electronics, energy conversion and motor-control applications.

Key benefits

  • Wide current range.
  • High accuracy.
  • Fast response time.
  • Galvanic isolation.
  • Compact and lightweight design.
  • High resistance material.
  • Operating temperature range from -40 °C to +125 °C.

Typical applications

  • Electrical vehicles.
  • Energy sources.
  • Switching power supply.
  • Welding machine power supply.
  • Battery and UPS.
  • Servo motor traction.
  • Energy monitoring.

Technical specifications

Reference OLT1000-04V-302
Nominal primary current 1000 A
Measurement range -3000 to +3000 Arms
Analog output voltage ±4 Vrms typ. at IPN
Supply voltage ±11 to ±18 VDC (±15 typ.)
Bandwidth 50 kHz typ.
Accuracy ±1 % typ. at IPN
Linearity ±0.5 % typ., ±1 % max.
Response time @ 90% 3 µs typ., 5 µs max.
Reaction time @ 10% 1 µs typ.
Offset voltage ±10 mV typ., ±20 mV max.
Hysteresis voltage ±10 mV typ., ±20 mV max.
Load resistance 1 to 10 kΩ
AC insulation voltage 3000 VAC min. (@ 50 Hz, 60 s and 0.1 mA)
Operating temperature -40 to +125 °C
Weight 490 g typ.
Primary aperture 64 mm x 22 mm rectangular opening
Fastening 2 x Ø5.5 mm
Output terminal Molex 5045-04AG

Compliance and standards

  • GB/T 7665-2005.
  • JB/T 7490-2007.
  • JB/T 25480-2010.
  • JB/T 9473-2020.
  • SJ 20792-2000.
  • CE.
  • ROHS.
  • FC.

Integration notes

  • The primary conductor temperature must not exceed 105 degC.
  • Respect supply voltage limits to avoid measurement saturation or sensor damage.
  • The final equipment manufacturer must validate insulation, thermal behavior, EMC performance and safety compliance in the complete system.